Top: f77 Up: 10 - Format_Specifiers
Previous: 10,28 - SS Next: 10,30 - TL
Section 10,29: T
Tn (Tab to Position n)
On input, starts the next read operation at the character position
(within the record) indicated by position n. For example, if an
input statement reads a record containing:
ABC XYZ
and this record is under the control of the FORMAT statement:
10 FORMAT (T7,A3,T1,A3)
On execution, the input statement would first read the characters
XYZ and then read the characters ABC.
On output, starts the next write operation at the character
position n in the external record.
The position specified must be an integer in the range 1 through
the size of the record.
Top: f77 Up: 10 - Format_Specifiers